Type the number marked on your fixture probe — for example GKS 100 307 150 A3000 — and the converter applies the manufacturer's own published rules to give the LH part. Below the tool are the rules themselves and every confirmed part-number pair, so you can check the answer rather than take it on trust.
Runs entirely in your browser. Nothing is sent anywhere until you email us.
These 17 pairs come straight from the manufacturer's cross-reference sheet. Where a row does not follow the rules cleanly, it is marked and explained underneath — we have not quietly deleted the awkward ones.
| INGUN | LH equivalent | Pitch | Tip | Note |
|---|---|---|---|---|
| GKS 003 206 254 A2000 | LH-200 C06 250 2N | — | 206, where the map gives 306 | Close recommendation B |
| GKS 050 214 050 A2800 | LH-078 B14 050 2.2N | 1.27 mm (.050) | 214 / B14 | Force differs A |
| GKS 050 291 050 A2000 | LH-078 B91 050 2N | 1.27 mm (.050) | 291 / B91 | — |
| GKS 075 214 050 A2800 | LH-102 B14 050 2.8N | 1.91 mm (.075) | 214 / B14 | — |
| GKS 075 214 064 A2000 | LH-102 B14 064 2N | 1.91 mm (.075) | 214 / B14 | — |
| GKS 075 225 120 A2800 | LH-102 B25 120 2.8N | 1.91 mm (.075) | 225 / B25 | — |
| GKS 075 291 064 A2800 | LH-102 B91 064 2.8N | 1.91 mm (.075) | 291 / B91 | — |
| GKS 075 303 120 A2800 | LH-102 C03 120 2.2N | 1.91 mm (.075) | 303 / C03 | Force differs A |
| GKS 100 214 050 A3000 | LH-137 B14 050 3N | 2.54 mm (.100) | 214 / B14 | — |
| GKS 100 214 130 A3000 | LH-137 B14 130 3N | 2.54 mm (.100) | 214 / B14 | — |
| GKS 100 225 130 A3000 | LH-137 B25 130 3N | 2.54 mm (.100) | 225 / B25 | — |
| GKS 100 291 090 A3000 | LH-137 B91 090 3N | 2.54 mm (.100) | 291 / B91 | — |
| GKS 100 303 150 A2000 | LH-137 C03 150 2N | 2.54 mm (.100) | 303 / C03 | — |
| GKS 100 303 150 A3000 | LH-137 C03 150 3N | 2.54 mm (.100) | 303 / C03 | — |
| GKS 100 305 090 A3000 | LH-137 C05 090 3N | 2.54 mm (.100) | 305 / C05 | — |
| GKS 100 307 150 A2000 | LH-137 307 150 2N | 2.54 mm (.100) | 307 / C07 | Tip written as number C |
| GKS 100 307 150 A3000 | LH-137 C07 150 3N | 2.54 mm (.100) | 307 / C07 | — |
Everything the converter does, it does with these four tables and nothing else. They are published so a competitor can be checked and so you can convert a number we have never seen.
| INGUN series | LH series | Pitch |
|---|---|---|
| GKS 040 | LH-061 | 1.00 mm (.039) |
| GKS 050 | LH-078 | 1.27 mm (.050) |
| GKS 075 | LH-102 | 1.91 mm (.075) |
| GKS 100 | LH-137 | 2.54 mm (.100) |
| GKS 003 | LH-200 | Large-pitch series |
| GKS 004 | LH-236 | Large-pitch series |
| LH | INGUN | LH | INGUN | LH | INGUN |
|---|---|---|---|---|---|
| B01 | 201 | C02 | 302 | B91 | 291 |
| B14 | 214 | C03 | 303 | B93 | 293 |
| B25 | 225 | C05 | 305 | B97 | 297 |
| B88 | 288 | C06 | 306 | B89 | 289 |
| C07 | 307 | — | — | — | — |
What each tip geometry does is on the tip-style page.
| INGUN force code | Spring force |
|---|---|
| A2000 | 2.0 N |
| A2800 | 2.8 N |
| A3000 | 3.0 N |
| INGUN | LH |
|---|---|
| KS-050 E08 | LHR078-08DX |
| KS-075 30G | LHR102-4S |
| KS-075 47G | LHR102-4W / LHR102-4FL |
| KS-100 30G | LHR137-4S |
| KS-100 47G | LHR137-4W / LHR137-4FL |
| KS-001 30G | LHPR102-3S |
| KS-001 47G | LHPR102-3W |
| KS-003 30G | LHR200-4S |
| KS-004 30G | LHR236-4S |
The factory has no written cross-reference for these. If you are holding one of their part numbers, send it — we compare against drawings case by case and tell you honestly when there is no match.
RF spring-contact probes, PCB probes, pogo pins and double-ended BGA probes are not in the numbering rules above, so the converter will not guess them. Ask and we answer from the drawing.
Gold thickness over nickel and mechanical life are not encoded in either manufacturer's part number and are not published here. They are confirmed per order against the specification you require.
Tell us the INGUN part marked on the probe, the pitch of your fixture and what you are testing. We reply with the LH part, what changes, and a price.